Central Chilling Module | 15 Ton | Air-Cooled | Single Zone
MA-20-RC-C
Click Here for An Immediate Factory Pricing Quote For the MA-20-RC-C ▶
Pricing Is Now On Display
Product Overview
Air-cooled central chilling module use mechanical refrigeration to cool recirculated fluids that support industrial process cooling applications.
20°F to 70°F process fluid temperature range.
This chiller combines one or more refrigeration circuits to chill fluid. A separate reservoir and pumping system is required to circulate chilled fluid to the use points.
Air-Cooled chillers use ambient air to dissipate the heat from the refrigeration system.
The refrigeration system and controls remain inside while the remote air-cooled condenser is located outside.
Price is Loading
Specifications
Model: MA-20-RC-C (1)
Refrigerant Zones
Quantity : 1
Compressor
Quantity : 1
HP : 20
Type : Scroll
(2)Total Capacity : 19
Refrigerant
Type : R-410A
Connection Sizes
To Process : 2"
From Process : 2"
Full Load Amperage(3)
230/3/60 : 82.0
460/3/60 : 41.0
575/3/60 : 33.0
Dimensions(5)
Height : 52"
Width : 24"
Depth : 70"
Weight(6)
Shipping : 885 lbs
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Consult factory for 50HZ operation.
Approximate dimensions. Not for construction purposes.
Unit weight crated for shipment. Weight shown for APT-RC unit only. Weight for remote air-cooled condenser shown separately.
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ " 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
Field charging by user required.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.