Temperature Control Unit | Oil Unit | 48kW 7.5HP | Heating and Cooling
VTO-7750HC-G
Click Here for An Immediate Factory Pricing Quote For the VTO-7750HC-G ▶
Pricing Is Now On Display
Product Overview
Price is Loading
Specifications
Model: VTO-7750HC-G (1)
Heater(2)
kW : 48
Process Pump
HP : 7.5
GPM : 100
PSI : 44
Fluid Volume(3)
Unit : 8 gal
Expansion : 7 gal
Maximum : 46 gal
Heat Exchanger
Capacity : 3.6 sq.ft.
Full Load Amperage(5)
230/3/60 : 143.6
460/3/60 : 72.3
575/3/60 : 57.8
Control Instrument
Type : G500 Series
Temperature Range : 100°F - 500°F
Connection Sizes
To Process : 2"
From Process : 2"
Water Supply : 1/2"
Drain : 1/2"
Dimensions
Height : 76"
Width : 27"
Depth : 45"
Weight(7)
Shipping : 870 lbs
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Derate heater output by 25% for 208/3/60 operation.
Maximum Total System @ 15% expansion = unit volume plus piping and prodcess volumes. Typical fluid expansion rates:
a. Paratherm OR : 4.00% per 100°F
b. Paratherm NF : 3.04% per 100°F
c. Multitherm PG-1 : 3.10% per 100°F
d. Calflo FG : 5.62 per 100°F
Do not use Mobiltherm 603.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Low pressure, high flow centrifugal pump
eliminates high pressure safety concerns
Custom designed pump casings produce higher
flow with less horsepower
Water cooled pump seal maintains seal integrity
and lengthens service life
Seal cooling is provided by facility water
circulated within a cast jacket surrounding
the seal area
Process Connections
Female NPT fittings standard on all process connections
To and From Process connections supplied with shut off valves
Supplied with manual process fluid purge system allowing purging of the process for storage within the unit expansion tank. Requires low pressure compressed air source for operation.
Cabinetry & Frame
Stainless steel enclosure panels
Hinged electrical panel
Heater
48 kW
Flange mounted reduces leak potential
Vertically mounted for easy servicing
Uses a steel heater sheath for a long life at
high fluid temperatures
Cooling Circuit
A water to oil heat exchanger is used to cool the circulated fluid
Cooling water flow to the heat exchanger is regulated by a solenoid valve controlled by the microprocessor control instrument
Expansion Tank & Reservoir
Large capacity expansion tank allows roomfor thermal expansion