Central Water Chiller | Outdoor Air-Cooled | 210 Ton
TTOACS-210D-MZC-2P
Click Here for An Immediate Factory Pricing Quote For the TTOACS-210D-MZC-2P ▶
Pricing Is Now On Display
Product Overview
These air-cooled central chillers use mechanical refrigeration to cool recirculated fluid that support industrial process cooling applications.
20°F to 70°F fluid temperature range.
Air-cooled water chillers use ambient air to dissipate process heat and efficiently runs in air temperature between -20°F to 95°F.
These systems are designed for outdoor installation in most types of climates. The air-cooled condenser, chiller zones, reservoir and pumping system are delivered as a complete package.
Price is Loading
Specifications
Model: TTOACS-210D-MZC-2P (1)
Refrigerant Zones
Quantity : 2
Capacity
(2)Tons : 204
kW : 717.4
Compressor
Type : Rotary Screw
Refrigerant
Type : R-407C
Air-Cooled Condenser
Quantity of Fans : 14
Evaporator
Type : Shell and Tube
Process Pump
(3)HP : 30
(4)GPM : 490
PSI : 60
Evaporator Pump
(3)HP : 15
(4)GPM : 490
Standby Pump
Offered : Optional
Connection Sizes
Type : Flanged
Size : 6"
Reservoir Capacity
Capacity : 900 gal
Construction : Stainless Steel
Dimensions(5)
Height : 99"
Width : 96"
Depth : 408"
Controller
Type : MZC Series
System Amperage(6)
460/3/60 : 542.0
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
Consult pump curve for exact pump performance.
Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
Approximate dimensions. Not for construction purposes.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Features
Refrigerant Circuit
Refrigerant sight glass with moisture indicator
Filter-drier
Thermostatic expansion valve
Liquid line solenoid valve
Condenser
Air-Cooled
Condenser shipped separately and requires field installation.
Remote, located outdoors
Heavy gauge galvanized steel cabinet on heavy duty legs
Enhanced copper tubing
with aluminum fins
with aluminum fins
Energy efficient motors
Direct drive fans
with quiet "swept wing" blades
with quiet "swept wing" blades
Non-fused power disconnect
Electrical
UL listed electrical components
UL508A enclosed electrical cabinet
Branch circuit protection of components
Fused transformer
Process pump motor starter
Compressor motor starter
Power entry terminal block
Electrical circuit has a standard SSCR rating of 5 kA
Coolant Circuit
Process pump
Discharge service valve
Large capacity
Suction service valve
Evaporator pump
Discharge service valve
Discharge suction valve
Options
Refrigerant Circuit
Condensers utilizing all EC fan motors for higher
energy efficiency
Oversized condensers for higher efficiency and full rated
performance in higher ambient conditions
Electrical
Main power disconnect switch
Control Instrument
Modbus TCP/IP RJ45
Remote control instrument display
Coolant Circuit
Automatic low flow bypass valve
Overhead piping kit
Supply & return isolation valves
Drain-back prevention system for use with overhead
piping systems
Standby Pump : 30 HP : TEFC Motor
Higher flow or pressure process pumps
Choice of reservoir construction; Rotationally molded
polyethylene or welded stainless steel